FAM132A Polyclonal Antibody-Invitrogen

  • 详细信息
  • 询价记录
  • 相关实验
  • 货号: PA546452
    抗体名: FAM132A Polyclonal Antibody
    靶点: FAM132A
    浓度: 0.5 mg/ml
    应用范围: Western Blot
    宿主: Rabbit
    适应物种: Human, Zebrafish
    克隆性: 单克隆
    保存条件: -20° C, Avoid Freeze/Thaw Cycles
    形态: Liquid
    亚型: IgG
    免疫原: Synthetic peptide directed towards the N-terminal of human FAM132A
    规格: 100 µl

nunc

ART3 Polyclonal Antibody

  • 详细信息
  • 询价记录
  • 相关实验
  • 技术资料
    • 货号:

      PA512128

    • 抗体名:

      ART3 Polyclonal Antibody

    • 靶点:

      ART3

    • 浓度:

      Lot-specific

    • 应用范围:

      Western Blot

    • 宿主:

      Rabbit

    • 适应物种:

      Human

    • 克隆性:

      单克隆

    • 保存条件:

      -20° C, Avoid Freeze/Thaw Cycles

    • 形态:

      Liquid

    • 亚型:

      IgG

    • 免疫原:

      KLH conjugated synthetic peptide between 280-310 amino acids from the C-terminal region of human ART3

    • 规格:

      400 µL

    风险提示:仅作为第三方平台,为商家信息发布提供平台空间。用户咨询产品时请注意保护个人信息及财产安全,合理判断,谨慎选购商品,商家和用户对交易行为负责。对于医疗器械类产品,请先查证核实企业经营资质和医疗器械产品注册证情况。

  • 该产品暂未上传技术资料

    免费索取技术资料

nunc

Jordi凝胶柱Jordi Gel DVB WAX Column 100Å 5µ 25cm 10mm

产品货号: 15090 产品名称: Jordi凝胶柱Jordi Gel DVB WAX Column 100Å 5µ 25cm 10mm 产品品牌: Jordi

Jordi凝胶柱Jordi Gel DVB WAX Column 100Å 5µ 25cm 10mm

详细介绍 Jordi(美国)联合公司生产体积排斥色谱(SEC)即凝胶渗透色谱 (GPC)和阴离子交换色谱(AEC)等色谱柱所用的填料均采用纯净的二乙烯苯(DVB)为原料,通过独特的聚合工艺制得184% DVB 聚合体填料。上海金畔生物供应美国Jordi各类色谱柱及相关耗材配件,更多产品详情,请来电咨询。

Jordi凝胶柱Jordi Gel DVB WAX Column Mixed Bed LS 5µ 50cm 10mm

产品货号: 15087 产品名称: Jordi凝胶柱Jordi Gel DVB WAX Column Mixed Bed LS 5µ 50cm 10mm 产品品牌: Jordi

Jordi凝胶柱Jordi Gel DVB WAX Column Mixed Bed LS 5µ 50cm 10mm

详细介绍 Jordi(美国)联合公司生产体积排斥色谱(SEC)即凝胶渗透色谱 (GPC)和阴离子交换色谱(AEC)等色谱柱所用的填料均采用纯净的二乙烯苯(DVB)为原料,通过独特的聚合工艺制得183% DVB 聚合体填料。上海金畔生物供应美国Jordi各类色谱柱及相关耗材配件,更多产品详情,请来电咨询。

总膳食纤维快速整合试剂盒 K-RINTDF Rapid Integrated Total Dietary Fiber Assay Kit

总膳食纤维快速整合试剂盒

英文名:Rapid Integrated Total Dietary Fiber Assay Kit

货号:K-RINTDF

规格:100 assays per kit

市场价: 4039元 

  • 应用范围:
  • This test kit is suitable for the measurement and analysis of Total Dietary Fiber as per Codex Alimentarius definition, updated to be more consistent with in vivo conditions in the human small intestine, i.e. a 4 h incubation time. Under these conditions more accurate measurement of resistant starch is obtained, including phosphate cross-liked starch (RS4). Use of higher enzyme concentrations ensures that resistant maltodextrins produced from non-resistant starch under the incubation conditions of the Integrated Total Dietary Fiber procedure (AOAC Methods 2009.01 and 2011.25 are no longer produced.
    In this rapid, improved method, the incubation time with PAA + AMG is reduced to 4 h and the levels of both PAA and AMG are increased to ensure that resistant starch levels obtained with a set of control samples are consistent with ileostomy data. Under these conditions, the DF values obtained for most samples are the same as those obtained with AOAC Methods 2009.01 and 2011.25.
    The dietary fiber fractions that are measured with this method are:
    1. High Molecular Weight Dietary Fiber (HMWDF) including Insoluble Dietary Fiber (IDF) and Low Molecular Weight Soluble Dietary Fiber (SDFS; soluble dietary fiber which is soluble in the presence of 78% aqueous ethanol), or
    2. Insoluble dietary fiber (IDF), Higher Molecular Weight Soluble Dietary Fiber (SDFP; water soluble dietary fiber that precipitates in the presence of 78% aqueous ethanol) and SDFS.
    The enzymes used in this method are high purity and effectively devoid of contaminating enzymes active on other dietary fiber components such as β-glucan, pectin and arabinoxylan. They are supplied as freeze-dried powders; allowing the use of glycerol as an internal standard.

    For the determination of Total Dietary Fiber in cereal products, foodstuffs, feeds and other materials. 

    Principle:
    (Pancreatic α-amylase + amyloglucosidase)
    (1) Non-resistant starch + H2O → D-glucose

    (protease)
    (2) Protein + H2O → peptides

    (3) IDF (including resistant starch) and alcohol precipitated 
    soluble DF (SDFP) determined gravimetrically

    (4) Alcohol soluble DF (SDFS) determined by HPLC

    (5) Ash and residual protein determined on DF residues 
    and subtracted

    Kit size:                             100 assays
    Method:                              Hydrolysis/removal of non-dietary
    fibre components
    Total assay time:                ~ 3 h work (over 1-2 days)
    Detection limit:                   0.5-100% of sample weight
    Application examples: 
    Food ingredients, food products and other materials
       

    * See McCleary, B. V., Sloane, N & Draga, A. (2015). Determination of total dietary fibre and available carbohydrates: a rapid integrated procedure that simulates in vivo digestion. Starch /Starke, 66, 1-24.

    Advantages

    • More rapid measurement – incubation time with PAA + AMG reduced to 4 h in comparison with AOAC 2009.01 (increased levels of enzyme employed)
    • DF values for most samples are very similar to those obtained with AOAC Method 2009.01
    • Rapid Integrated Total Dietary Fiber method removes all of the limitations that have been identified with AOAC Method 2009.01*
    • All reagents stable for > 2 years after preparation
    • The method is consistent with the CODEX Alimentarius definition of dietary fiber
    • Mega-Calc™ software tool is available from our website for hassle-free raw dataprocessing
    • Very competitive price (cost per test)

     

     Q1. How should I prepare the required 78% ethanol solution?

    A volume reduction occurs on mixing water with 95% ethanol (or IMS). 1 L of 78% ethanol is prepared by adding 821 mL 95% ethanol (or IMS) to 207 mL H2O.
    If using a 1 L volumetric flask, this is best accomplished by placing 821 mL 95% ethanol (or IMS) into the volumetric flask. Dilute to volume with deionised water. Mix well. Check the level and if necessary add more deionised water to bring it back up to the 1 L mark.

 

Jordi凝胶柱Jordi Gel DVB Column Mixed Bed LS 5µ 30cm 7.8mm

产品货号: 15077 产品名称: Jordi凝胶柱Jordi Gel DVB Column Mixed Bed LS 5µ 30cm 7.8mm 产品品牌: Jordi

Jordi凝胶柱Jordi Gel DVB Column Mixed Bed LS 5µ 30cm 7.8mm

详细介绍 Jordi(美国)联合公司生产体积排斥色谱(SEC)即凝胶渗透色谱 (GPC)和阴离子交换色谱(AEC)等色谱柱所用的填料均采用纯净的二乙烯苯(DVB)为原料,通过独特的聚合工艺制得173% DVB 聚合体填料。上海金畔生物供应美国Jordi各类色谱柱及相关耗材配件,更多产品详情,请来电咨询。

Jordi凝胶柱Jordi Gel DVB Column 100000Å 5µ 30cm 7.8mm

产品货号: 15074 产品名称: Jordi凝胶柱Jordi Gel DVB Column 100000Å 5µ 30cm 7.8mm 产品品牌: Jordi

Jordi凝胶柱Jordi Gel DVB Column 100000Å 5µ 30cm 7.8mm

详细介绍 Jordi(美国)联合公司生产体积排斥色谱(SEC)即凝胶渗透色谱 (GPC)和阴离子交换色谱(AEC)等色谱柱所用的填料均采用纯净的二乙烯苯(DVB)为原料,通过独特的聚合工艺制得170% DVB 聚合体填料。上海金畔生物供应美国Jordi各类色谱柱及相关耗材配件,更多产品详情,请来电咨询。

Jordi凝胶柱Jordi Gel DVB Glucose Column Mixed Bed 5µ 25cm 10mm

产品货号: 15065 产品名称: Jordi凝胶柱Jordi Gel DVB Glucose Column Mixed Bed 5µ 25cm 10mm 产品品牌: Jordi

Jordi凝胶柱Jordi Gel DVB Glucose Column Mixed Bed 5µ 25cm 10mm

详细介绍 Jordi(美国)联合公司生产体积排斥色谱(SEC)即凝胶渗透色谱 (GPC)和阴离子交换色谱(AEC)等色谱柱所用的填料均采用纯净的二乙烯苯(DVB)为原料,通过独特的聚合工艺制得162% DVB 聚合体填料。上海金畔生物供应美国Jordi各类色谱柱及相关耗材配件,更多产品详情,请来电咨询。

Acros超干溶剂 Acetonitrile, 99.9+%, Extra Dry, AcroSeal«

  • 详细信息
  • 询价记录
  • 相关实验
  • 技术资料
    • 供应商:

      Fisher Scientific

    • CAS号:

      75-05-8

    • 英文名:

      Acetonitrile, 99.9+%, Extra Dry, AcroSeal«

    AcroSeal 超干溶剂:有三个不同的级别,包装时的水含量低于50ppm。

    ● 标准级别:适用于普通的应用。
    ● 分子筛级别:包装内含有分子筛,延长使用寿命。
    ● 最高级别:经0.2 微米过滤器过滤,适用于无污染的应用。

    温馨提示:不可用于临床治疗。

    风险提示:仅作为第三方平台,为商家信息发布提供平台空间。用户咨询产品时请注意保护个人信息及财产安全,合理判断,谨慎选购商品,商家和用户对交易行为负责。对于医疗器械类产品,请先查证核实企业经营资质和医疗器械产品注册证情况。

  • 该产品暂未上传技术资料

    免费索取技术资料

nunc

Jordi凝胶柱Jordi Gel DVB Column 1000Å 5µ 30cm 7.8mm

产品货号: 15072 产品名称: Jordi凝胶柱Jordi Gel DVB Column 1000Å 5µ 30cm 7.8mm 产品品牌: Jordi

Jordi凝胶柱Jordi Gel DVB Column 1000Å 5µ 30cm 7.8mm

详细介绍 Jordi(美国)联合公司生产体积排斥色谱(SEC)即凝胶渗透色谱 (GPC)和阴离子交换色谱(AEC)等色谱柱所用的填料均采用纯净的二乙烯苯(DVB)为原料,通过独特的聚合工艺制得168% DVB 聚合体填料。上海金畔生物供应美国Jordi各类色谱柱及相关耗材配件,更多产品详情,请来电咨询。

Jordi凝胶柱Jordi Gel DVB Glucose Column 10000Å 5µ 25cm 10mm

产品货号: 15063 产品名称: Jordi凝胶柱Jordi Gel DVB Glucose Column 10000Å 5µ 25cm 10mm 产品品牌: Jordi

Jordi凝胶柱Jordi Gel DVB Glucose Column 10000Å 5µ 25cm 10mm

详细介绍 Jordi(美国)联合公司生产体积排斥色谱(SEC)即凝胶渗透色谱 (GPC)和阴离子交换色谱(AEC)等色谱柱所用的填料均采用纯净的二乙烯苯(DVB)为原料,通过独特的聚合工艺制得160% DVB 聚合体填料。上海金畔生物供应美国Jordi各类色谱柱及相关耗材配件,更多产品详情,请来电咨询。

Jordi凝胶柱Jordi Gel DVB Column 500Å 5µ 30cm 7.8mm

产品货号: 15071 产品名称: Jordi凝胶柱Jordi Gel DVB Column 500Å 5µ 30cm 7.8mm 产品品牌: Jordi

Jordi凝胶柱Jordi Gel DVB Column 500Å 5µ 30cm 7.8mm

详细介绍 Jordi(美国)联合公司生产体积排斥色谱(SEC)即凝胶渗透色谱 (GPC)和阴离子交换色谱(AEC)等色谱柱所用的填料均采用纯净的二乙烯苯(DVB)为原料,通过独特的聚合工艺制得167% DVB 聚合体填料。上海金畔生物供应美国Jordi各类色谱柱及相关耗材配件,更多产品详情,请来电咨询。

Jordi凝胶柱Jordi Gel DVB Glucose Column Mixed Bed LS 5µ 50cm 10mm

产品货号: 15057 产品名称: Jordi凝胶柱Jordi Gel DVB Glucose Column Mixed Bed LS 5µ 50cm 10mm 产品品牌: Jordi

Jordi凝胶柱Jordi Gel DVB Glucose Column Mixed Bed LS 5µ 50cm 10mm

详细介绍 Jordi(美国)联合公司生产体积排斥色谱(SEC)即凝胶渗透色谱 (GPC)和阴离子交换色谱(AEC)等色谱柱所用的填料均采用纯净的二乙烯苯(DVB)为原料,通过独特的聚合工艺制得156% DVB 聚合体填料。上海金畔生物供应美国Jordi各类色谱柱及相关耗材配件,更多产品详情,请来电咨询。